NCF Editor: Order Tab

The Order tab allows you to specify the output code and a string for each block order. It is accessed from the NCF Editor dialog.

Code

Item   Description
EOB   Displays the "End of Block" value that you specify in the Select Character dialog. This dialog is displayed by clicking . You can specify a character, space or control code.
 

Displays the Select Character dialog. This dialog allows you to specify a character, space or control code for the EOB value.
EOR   Displays the "End of Record" value that you specify in the Select Character dialog. This dialog is displayed by clicking . You can specify a character, space or control code.
  Displays the Select Character dialog. This dialog allows you to specify a character, space or control code for the EOR value.
FEED   Displays the FEED value that you specify in the Select Character dialog. This dialog is displayed by clicking . You can specify a character, space or control code.
  Displays the Select Character dialog. This dialog allows you to specify a character, space or control code for the FEED value.
D code   The following values can be specified for D codes.
  Address character Specify an address character code. Enter a single, uppercase, alphabetic character.
  Initial value Specify the initial value of the code number. Enter a value between 0 and the value specified in the Maximum number of digits field.
  Increment Specify the value that is used to increment the code number. Enter a value between 0 and the value specified in the Maximum number of digits field.
  Maximum number of digits Specifies the maximum number of digits of the code number. Enter a value between 1 and 9.
  Add 0s for max. number of digits Allows you to specify whether zeros are added to achieve the maximum number of digits that you specify in the Maximum number of digits box.
  • Selected: Zeros are added to achieve the maximum number of digits that you specify in the Maximum number of digits box.
  • Not selected: Zeros are not added to achieve the maximum number of digits that you specify in the Maximum number of digits box.

Block order format

Item   Description
Order name   Lists the block orders for which you can specify a macro command. Specify a macro command for a block order by pointing the cursor in the Block order column, for the relevant row, and then clicking the displayed button. Select a macro command in the displayed Add Macro command dialog.
  Program start Allows you to specify a program start order string.
  Drill hit Allows you to specify a drill hit order string. This field is not displayed for photo data.
  Move Allows you to specify a move order string.
  Line Allows you to specify a line order string.
  Flash Allows you to specify a flash order string.
  Arc (Clockwise) Allows you to specify an Arc (Clockwise) order string.
  Arc (Counter-clockwise) Allows you to specify an Arc (Counter- clockwise) order string.
  Select apertures Allows you to specify a Select apertures order string.
  Select tools Allows you to specify a Select tools order string.
  Optional stop Allows you to specify an Optional stop order string.
  Program stop Allows you to specify an program stop order string.
  Polygon start Allows you to specify a polygon start order string.
  Polygon end Allows you to specify an polygon end order string.
  slot Slot order string
Block order   Specify a string for the relevant block order by typing it in the relevant cell. Alternatively, point the cursor in this cell and then click the displayed button. Select a string in the displayed Add Macro command dialog.

Modal format

Allows you to specify the strings that are assigned to codes in the modal format. Add a row to this table by right-clicking it and selecting Add Group on the assist menu. Delete a row by right-clicking it and selecting Delete Group on the assist menu. If you specify a value in the highest Code [number] column, then another column is automatically created. It is named Code [number + 1].

Value   Description
Initial value   Allows you to select a code number as an initial value. Code numbers can be selected for which you have assigned values.
  None No initial value is specified.
  [Code number] Displays the code number that you select as the initial value. Code numbers can be selected for which you have assigned values.
Code 2   Shows the string for Code 2 that is used for the modal format. Specify a string by typing it in the relevant cell. Alternatively, point the cursor in this cell and then click the displayed button. Select a value in the displayed Add Macro command dialog.
Code 3   Shows the string for Code 3 that is used for the modal format. Specify a string by typing it in the relevant cell. Alternatively, point the cursor in this cell and then click the displayed button. Select a value in the displayed Add Macro command dialog.
Code 4   Shows the string for Code 4 that is used for the modal format. Specify a string by typing it in the relevant cell. Alternatively, point the cursor in this cell and then click the displayed button. Select a value in the displayed Add Macro command dialog.