Operating Point Display

The Operating Point Display command displays the operating point voltage for all nets on the schematic sheet. This is simulated by the LTspice application. To launch this command, click Analysis > SPICE Controller > Operating Point Display on the eCADSTAR Schematic Editor ribbon. If multiple simulation results exist, then select a result from the displayed Parameter select dialog.

To display the operating point voltage on the canvas for individual nets, select a net on the canvas. The property SPICE OP Voltage is displayed in the Properties Panel. To toggle its display on the canvas, right-click this row and select either Display Viewer or Hide Viewer on the assist menu.

 

Note
This command is made unavailable in the following circumstances.
  • The "-ascii" command line argument is not set in the Application Settings dialog for the SPICE Controller.
  • The current schematic sheet is read-only.
  • A SPICE Controller license is not found.